| Input DC (PV side) |
| Recommended max. PV array size |
6 kW |
7.2 kW |
10 kW |
12 kW |
16 kW |
20 kW |
| Max. usable PV input power |
4.8 kW |
5.76 kW |
8 kW |
9.6 kW |
12.8 kW |
16 kW |
| Max. input voltage |
500 V |
| Rated voltage |
330 V |
| Start-up voltage |
90 V |
| MPPT voltage range |
90 - 435 V |
| Max. input current |
|
|
16 A / 16 A |
|
32 A / 32 A |
42 A / 42 A |
| Max. short circuit current |
|
|
20 A / 20 A |
|
40 A / 40 A |
48 A / 48 A |
| MPPT number / Max. input strings number |
|
|
2 / 2 |
|
|
2 / 4 |
| Battery |
| Battery type |
Li-ion / Lead-acid |
| Battery voltage range |
40 - 60 V |
| Max. charge / discharge power |
3 kW |
3.6 kW |
5 kW |
6 kW |
8 kW |
10 kW |
| Max. charge / discharge current |
70 A |
80 A |
112 A |
135 A |
190 A |
210 A |
| Communication |
CAN / RS485 |
| Output AC (Grid side) |
| Rated output power |
3 kW |
3.6 kW |
5 kW |
6 kW |
8 kW |
10 kW |
| Max. apparent output power |
3 kVA |
3.6 kVA |
5 kVA |
6 kVA |
8 kVA |
10 kVA |
| Operation phase |
L/N/PE |
| Rated grid voltage |
220 V / 230 V |
| Rated grid frequency |
50 Hz |
| Rated grid output current |
13.7 A / 13.1 A |
16.4 A / 15.7 A |
22.8 A / 21.8 A |
27.3 A / 26.1 A |
36.4 A / 34.8 A |
45.5 A / 43.5 A |
| Max. output current |
13.7 A / 13.1 A |
16.4 A / 15.7 A |
22.8 A / 21.8 A |
27.3 A / 26.1 A |
36.4 A / 34.8 A |
45.5 A / 43.5 A |
| Power factor |
> 0.99 (0.8 leading - 0.8 lagging) |
| THDi |
< 3% |
| Input AC (Grid side) |
| Input voltage range |
187 - 253 V |
| Max. input current |
21 A |
25 A |
32 A |
40 A |
50 A |
65 A |
| Frequency range |
45 - 55 Hz / 55 - 65 Hz |
| Output AC (Back-up) |
| Rated output power |
3 kW |
3.6 kW |
5 kW |
6 kW |
8 kW |
10 kW |
| Max. apparent output power |
2 times of rated power, 10 s |
| Back-up switch time |
< 4 ms |
| Rated output voltage |
L/N/PE, 220 V / 230 V |
| Rated frequency |
50 Hz |
| Rated output current |
13.7 A / 13.1 A |
16.4 A / 15.7 A |
22.8 A / 21.8 A |
27.3 A / 26.1 A |
36.4 A / 34.8 A |
45.5 A / 43.5 A |
| Max. AC passthrough current |
35 A |
35 A |
40 A |
40 A |
50 A |
65 A |
| THDv (@linear load) |
<2% |
| Efficiency |
| Max. efficiency |
96.2% |
| EU efficiency |
96.1% |
| BAT charged by PV / AC max. efficiency |
95.3% / 93.9% |
| BAT discharged to AC max. efficiency |
93.8% |
| Protection |
| Anti-islanding protection |
Yes |
| Ground fault monitoring |
Yes |
| DC reverse-polarity protection |
Yes |
| Integrated AFCI 2.0 |
Optional |
| Protection class / Over voltage category |
I / II (PV and BAT), III (MAINS and BACKUP and GEN)
|
| General Data |
| Dimensions (W × H × D) |
335 × 560 × 253 mm |
| Weight |
23 kg |
23.5 kg |
|
23.8 kg |
| Topology |
High frequency isolation (for battery) |
| Operating ambient temperature range |
-25 ~ +60°C |
| Relative humidity |
0 - 100% |
| Ingress protection |
IP66 |
| Noise emission (typical) |
< 65 dB(A) |
| Cooling concept |
Natural cooling |
Intelligent fan-cooling |
| Max. operation altitude |
3000 m |
| Features |
| DC connection |
MC4 plug (PV port) / Terminal Block (BAT port)
|
| AC connection |
Terminal Block |
| Display |
7.0" LCD display & Bluetooth + APP
|
| Communication |
RS485, CAN, Optional: Wi-Fi, GPRS, LAN
|